SYS-6. Filters, cable length and losses
Design drive trains for four pumps (all have identical parameters: flow 250 l/s, head 280 m, efficiency 87%, rated speed 1450 rpm). Distance to the respective pumps from the electric room (with 6 kV voltage source) where the system driving the pumps are installed: 40 m, 250 m, 400 m, 1000 m.
Try systems with LV and MV FC.
First, set cable on «automatic selection». Then try higher and lower cross-sections. Compare the results. Change cable material from Copper to Aluminum. Compare the results. Summarize your findings in a table.