FC-5. Overloads

Design drive trains for the six different conveyors. Each conveyor is to be driven by one motor. System topology is the same for all the conveyors: gearbox 1:5 (type: helical). Grid voltage is 400 V.

Parameters (the same for all the conveyors):

  • torque 10 kNm, speeds: min - 100 rpm, max - 200 rpm.

The difference between the conveyors is in the overload patterns according to the table below. Conveyors 1-4 have overload due to technological processes. Conveyors 5 and 6 have overload due to heavy start. Reflect on motor thermal cycling.

Overloads 1 2 3 4 5 6
Amplitude 10% 10% 50% 50% 100% 100%
Duration 1 min each 10 min 1 min each 2 min 1 min each 10 min 1 min each 2 min 2 s each 60 s 10 s each 60 s
FC type
FC price
EM type
EM price